- CY series spreaders are used for many tasks in confined access situations.
- CY0109G is used for very confined situations and CY0122 is used for greater spreading distance.
- CY0109G and CY0122 models are supplied with AZ3140 high flow female couplers.
WARNING: Never disconnect the hose when the system is pressurized. Never exceed the maximum working pressure of the hose.
SPECIFICATIONS:
- Maximum Operating Pressure (bar): 700
- Maximum Spread (mm): 90
- Capacity (metric tons): 1
- Capacity (kN): 10
- Stroke (mm): 75
- Tip Clearance (mm): 15
- Cylinder Effective Area (cm2): 7
- Oil Capacity (cm3): 10
- Weight (kg): 2
DIMENSIONS:
- Dimension A (mm): 15
- Dimension B (mm): 90
- Dimension C (mm): 168
- Dimension E (mm): 29
- Dimension F (mm): 55
- Dimension J (mm): 55
Minimum Sale Qty: | 1 |